Skip to content

Lakewood Model 1575e Boiler Conductivity Controller

The Lakewood Model 1575e Boiler Conductivity Controller uses the latest in microprocessor capability, giving the user a high level of application flexibility. A large illuminated graphics screen, multiple inputs, and very easy setup characterize this new technology. The Model 1575e is ETL approved.

Features
  • Removable power cord and receptacles for simple conduit installations.
  • Scheduled feed, which can use three relays for biocides or other chemicals.
  • Two (2) water meter inputs, two (2) drum switch inputs, conductivity input, flow switch input, 4-20 mA output, and remote conductivity input via 4-20 mA are all standard features.
  • Designed with a single circuit board for better reliability and lower cost.
  • Large open shallow enclosure for easy wiring.
  • Ball valve delay feature allows accurate control of motorized ball valves.
  • Heavy-duty stainless steel domed numeric keypad and illuminated graphical display allow for quick and easy programming. Steel domed switches improve the tactile sensing and life expectancy of the keypad.
  • LED indicators for power, alarm and relay status.
Benefits
  • Easy to program with the Lakewood plain English, intuitive, and user friendly menu interface.
  • Controller can be used in boiler, cooling tower, or condensate applications when used with the appropriate conductivity sensor.
  • Single circuit board design improves reliability.
  • No add-on options. 4-20 mA output and feed schedule clock features are standard.
Specifications
Conductivity range 500-8000 mS for Boilers
Conductivity sensor 2 electrode
Conductivity Resolution +/-10 µS (conductivity <5000 mS)
+/-100µS (conductivity <5000 mS)
Temperature comp. 500NTC, NONE
Accuracy & repeatability +/-1.0%
Deadband/Setpoint Programmable
Auto/Manual outputs Menu selectable
Keypad 16 tactile push-buttons
Display illuminated 128×64 pixel LCD
Drum Switch Inputs 2 digital contact inputs
Water meter inputs (2) Contact head, paddle
Wheel or turbine
Timers Max. blowdown time exceeded
And relay run time exceeded
Output Signal One 4-20 mA, isolated or
Non-isolated optionally powered
Output for conductivity
Input Signal One 4-20 mA, non- isolated
Internally powered input for
Conductivity
Output relays 4, 3 selectable use,
1 blowdown
Relay ratings 3A each, 10A total
Power 120/240 VAC 50/60 Hz
Ambient 32º – 120ºF (0º – 49ºC)
Enclosure NEMA 4X, ETL
Sensors/Plumbing Boiler
Max Pressure 600 psi (41.3 bar)
Max Temp 486ºF (252ºC)